CAPACITY EVALUATION OF EXISTING 70-YEAR-OLD COFFERDAM ANCHORAGE
Location: Nova Scotia
​
Scope:
-
Determine the design strength of the anchorage system for the steel sheet pile cofferdam. This is the second phase of a project that evaluated the characteristics strength of the sheet pile interlock.
​​
Complexity:
-
Uncertainty about the concrete integrity.
-
Lack of adequate documentation related to anchorage strength.
-
Complex load path and difficulty of performing in-situ strength evaluation.
​​
Approach / Value
-
A nonlinear finite element (NFE) model of the anchorage was developed and utilized to predict the cofferdam capacity. The model offers an economical alternative to destructive in-situ testing of the anchorage.
-
The uncertainty in the anchorage-concrete strength was considered in the analysis.
-
Concrete strength parameters of the model were calibrated based on concrete core testing.